Home small skills: Fluorescent lamp common troubleshooting steps

In our lives, fluorescent lamps should be said to be more common lamps. In many family rooms, most of them will be lit by two or more lamps. Basically, there will be fluorescent lamps, which can be emitted more than many lamps. It also needs bright light and soft light, which has been widely used. Let's take a look at the common troubleshooting steps of fluorescent lamps !

日光灯

fluorescent lamp

First, the lamp does not shine at all

In this case, you can check the following steps:

1. Start other indoor lighting fixtures to see if the power supply is normal.

2. If the power supply of the road is normal, use the test pencil to check the switch terminal to see if the contact is good.

3. Use both hands to turn the lamp holder at both ends of the lamp tube a few times or turn the lamp tube to check if the lamp holder is in good contact with the lamp tube pin.

4. Rotate the starter to check whether the contact performance of the starter and the starter seat is good.

5. There is no thick oxide layer on the surface of the starter foot. If there is any oxide layer removed, the wiring between the components is intact.

日光灯常见故障

Fluorescent lamp common fault

Second, the two ends of the lamp flash, can not be normally illuminated

1. It may be that the voltage of the whole circuit is insufficient. At this time, other lamps in the room can be turned on. If the light is found to be darker than usual, it is sure that the circuit voltage is insufficient. After the power supply is normal, it will return to normal.

2. It may be that the starter is faulty. At this time, a new starter can be replaced. If it is an emergency repair, there is no new starter on hand. You can remove the opener shell and connect the paper capacitors in parallel with the jumper. Cut it for emergency use, but you must replace it with a new starter as soon as possible.

3, the indoor temperature is too low in the cold weather, the lamp is difficult to take off. At this time, you can use a hot towel to stick back and forth in the middle of the tube. Never touch the aluminum shell at both ends of the tube with a wet towel to prevent electric shock, and the tube can normally emit light.

Third, the two ends of the tube are red, and will automatically go out soon.

日光灯常见故障检修

Fluorescent lamp common troubleshooting

1. If the lamp is used for a long time, gradually blackening from the two ends, to red, there is a gradual process, basically the lamp is aging, the filament is about to blow off the precursor, and the lamp can be replaced to eliminate the fault.

2, the use of the lamp has been normal, the above phenomenon suddenly occurs, which is mostly caused by the failure of the rectifier, the rectifier can be replaced.

The above is the knowledge of the common troubleshooting steps for fluorescent lamps shared by you. I hope to help you. If you want to know more about fluorescent lamps, please continue to pay attention to the net. Get a quote for 10 seconds and get four sets of design solutions for free. You can also follow the whole process of decorating the housekeeper and take action!

Halogen Operating Light

1.ZF series of reflective shadowless lamp is widely used in various occasions operation lighting needs, is the ideal lighting equipment of modern operation room.

2. Full close streamline lamp body design completely meets the demand of the sterilization and high standard of laminar flow purification in operation room.

3. Adopting more than 5280 slices of reflection mirror, guaranteeing 1200 mm lighting depth.

4. Special design of color temperature compensation provides closer to that of natural sunlight and helps the doctor to distribute operation parts clearly and accurately.

5. The back-up battery will start work within 0.2 seconds automatically in case the main battery is damaged,ensuring the continuation of surgical operation. There`s failure indication in the handle control panel, to recommend the bulb to be changed after operation.

6. detachable handle jacket ,can be used for high temperature (≤134℃)sterilized.

7. Digital-control circuit offers many functions, with 10 segment brightness selection stepless lighting regulation, brightness memory, low voltage

start-up and power on self test etc.

8. The life-span of OSRAM halogen bulb is up to 1500 hours; the bulbs can be changed easily.

9. Germany ORSAM lamp socket,thermostability

10.Balance arm can be optional Germany imported or domestic.

11. mould Die-casting Eight edge type Revolving arm


Halogen Operating Light

Halogen Surgical Operating Light


Halogen Operating Light,Halogen Light Bulbs,Halogen Surgical Operating Light,Halogen Surgery Light

Shandong qufu healthyou Medical Technology co.,Ltd , https://www.kangerjianmedical.com